Product Features Description
Sicore II Installation and Commissioning Guide
667/HB/52600/000 Issue 2 Unrestricted
20
4.2.2.
Digital Outputs
Four isolated digital outputs are provided. These outputs have the following specification:
•
Protected Open Drain outputs *
•
Maximum operating voltage: 50V DC
•
Maximum operating current: 500mA
•
ELV level isolation
•
Programmable polarity
•
Output 4 can be assigned as sync output function
* - Protection from, over voltage transients, over current and over temperature operation.
4.2.3.
Power Switch
This interface provides a mechanism for switching an externally supplied voltage on or off.
This interface has the following specification:
•
Protected solid state single pole switch
•
Maximum operating voltage: 24V DC
•
Maximum operating current: 500mA
•
ELV level isolation
•
Programmable polarity
4.2.4.
Relay Output
This interface provides an isolated solid state changeover contact. This interface has the
following specification:
•
Protected solid state single pole changeover contact
•
Maximum operating voltage: 50V DC
•
Maximum operating current: 100mA
•
TR2523 compatible output
•
Fuse protected (factory repair only)
•
ELV level isolation
4.3.
WiFi Interface
The WiFi interface is a factory fit option and allows the user to connect locally to the cameras
WiFi hotspot using a WiFi device such as a Laptop, Tablet or Smart Phone. The Sicore II
camera WiFi operates on 2.4GHz & 5GHz bands and has a useable range of 10-30m
depending on location and ambient noise floor.
For security purposes the WiFi hotspot is disabled by default, refer to the Sicore II Operating
Instructions Handbook (Ref para. 1.3)