Technical Specification
Sicore II Installation and Commissioning Guide
667/HB/52600/000 Issue 2 Unrestricted
82
Parameter
Range
Power Supply
24V DC +10% -30% Negative Earth
[16.8 – 26.4V at the camera]
Transients
To BS EN50293:2001
Power Consumption
25W nominal
Power break support times
−
Voltage drop < 20 ms: no effect, device
will continue functioning normally
Size
450mm(L) x 280mm(W) x 180mm(H) approx
Weight
5.8Kg excluding mounting bracket
Operating Temperature Range
-30°C to +60°C
Operating Humidity Range
Up to 95% non-condensing
Protection
IP66
Material / Finish
Black anodized aluminium
Polycarbonate front window and sun shield
Stainless steel fixing screws
Approvals
Designed to meet the relevant sections of:
EN50293 Electromagnetic compatibility. Road
traffic signal systems
EN50556 Road traffic signal systems
TR2522A Remote Monitoring and Control of
Traffic Control Equipment via a
Telecommunications Network
TR2523 – Traffic Control Equipment
Interfacing Specification
CE Approved
RoHS Compliant