System Components
Sicore II Installation and Commissioning Guide
667/HB/52600/000 Issue 2 Unrestricted
30
5.6.1.
Cable Connections
All three cables (Main, Aux1, Aux2) use the same cable form. This cable is described in Table
8.
No.
Colour
Core Set
Description
1
Red
1
Cat5e Data Cable
2
Orange
1
Cat5e Data Cable
3
Blue
1
Cat5e Data Cable
4
White
1
Cat5e Data Cable
5
Brown
1
Cat5e Data Cable
6
Yellow
1
Cat5e Data Cable
7
Green
1
Cat5e Data Cable
8
Black
1
Cat5e Data Cable
9
Brown
2
3 pairs
10
White
2
3 pairs
11
Grey
2
3 pairs
12
Pink
2
3 pairs
13
Yellow
2
3 pairs
14
Green
2
3 pairs
15
Red
3
1.5mm
2
16
Black
3
1.5mm
2
Table 8 – Cable Cores
The cable makeup core sets are shown in Figure 7.
Core set 1 – Ethernet style
Core set 3 – 1.5mm
2
Power
Core set 3 – 1.5mm
2
Power
Core set 2 – 3 Pairs
Figure 7 – Cable Makeup
Ensure the Main Cable screen is terminated to the enclosure Ground – This
should be done at the cable gland entry point using a suitable screen clamp
arrangement. An example arrangement is shown in Figure 8