Commissioning
Sicore II Installation and Commissioning Guide
667/HB/52600/000 Issue 2 Unrestricted
57
7. Commissioning
The commissioning setup will vary greatly depending upon the backend system in use and
the network configuration. This handbook provides a description of a typical commissioning
procedure as a guide. This guide provides a simple setup delivering evidential records onto a
PC with basic optimisations for ANPR performance. As an overview this setup comprises:
•
Fixed IP via wired Ethernet interface
•
Time source via GPS
•
Monochrome Overview offset (if required)
•
Camera Calibration
•
Region Of Interest
•
Result Creation
•
Records delivered via CIFS using the Simple Uploader
To adapt this setup refer to the detailed description of all Web Interface settings in the Sicore
II Operating Instructions Handbook (Ref para. 1.3)
Note : To ensure that the camera is secure, the Security Configuration process
(Ref section 8) must be undertaken immediately after the basic commissioning
is complete
7.1.
Set site specific IP address
Connect to the camera as described in para 6.8.1.4
From the top menu select
Status and Configuration
On the left hand menu click on the + to expand
System
In the same way select
Settings then Comms then DSL/Fibre
The default Ethernet configuration page will be displayed: