Three lane application – Nominal 9.5m capture width at plate height
W
[m]
W1
[m]
H
[m]
D
[m]
V
[m]
V1
[m]
b
[deg]
f
[mm]
DCS
[m]
DCN
[m]
S
[m]
Max
angle
check
[Deg]
10.9
9.5
4
23.9
140.5
12.7
9.5
25
24.2
21.2
0
16
10.9
9.5
4
22.5
139.7
12.7
9.5
25
24.2