Marking for the customs union
EAC (Eurasian Conformity)
Eurasian Economic Union of Russia, Belarus, Armenia, Kazakhstan and Kyrgyzstan
Declaration of conformity according to the technical regulations of the customs union (TR ZU)
Mechanical stability (in operation)
Device
IEC 60068-2-27 shock
IEC 60068-2-6 vibration
15 g, 11 ms duration
6 shocks per axis
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
SCALANCE XP208
●
●
SCALANCE XP208EEC
●
●
SCALANCE XP208PoE EEC
●
●
SCALANCE XP216
●
●
SCALANCE XP216EEC
●
●
SCALANCE XP216PoE EEC
●
●
Installation guidelines
The devices meet the requirements if you adhere to the installation and safety instructions
contained in this documentation and in the following documentation when installing and
operating the devices.
• "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (
support.industry.siemens.com/cs/ww/en/view/27069465
• "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (
support.industry.siemens.com/cs/ww/en/view/84922825
• "EMC Installation Guidelines" configuration manual (
support.industry.siemens.com/cs/ww/en/view/60612658
WARNING
Personal injury and property damage can occur
The installation of expansions that are not approved for SIMATIC NET products or their target
systems may violate the requirements and regulations for safety and electromagnetic
compatibility.
Only use expansions that are approved for the system.
Note
The test was performed with a device and a connected communications partner that also meets
the requirements of the standards listed above.
When operating the device with a communications partner that does not comply with these
standards, adherence to the corresponding values cannot be guaranteed.
Approvals
SCALANCE XP-200
94
Operating Instructions, 03/2021, C79000-G8976-C428-08