![Siemens SCALANCE XP208EEC Operating Instructions Manual Download Page 83](http://html.mh-extra.com/html/siemens/scalance-xp208eec/scalance-xp208eec_operating-instructions-manual_383838083.webp)
8.5
Cable lengths
The cable lengths listed below apply to the SCALANCE XP-200.
Cable
Permitted cable length
IE TP torsion cable
with IE FC Outlet RJ-45 + 10 m TP cord
0 to 45 m
+ 10 m TP cord
IE TP torsion cable
with IE FC RJ-45 Plug 180
0 to 55 m
IE FC TP Marine / Trailing / Flexible cable
with IE FC Outlet RJ-45 + 10 m TP cord
0 to 75 m
+ 10 m TP cord
IE FC TP Marine / Trailing / Flexible cable
with IE FC RJ-45 Plug 180
0 to 85 m
IE FC TP standard cable
with IE FC Outlet RJ-45 + 10 m TP cord
0 to 90 m
+ 10 m TP cord
IE FC TP standard cable
with IE FC RJ-45 Plug 180
0 to 100 m
Technical specifications
8.5 Cable lengths
SCALANCE XP-200
Operating Instructions, 03/2021, C79000-G8976-C428-08