Restoring the factory defaults during operation
You can reset the device to the factory defaults during operation, see section "RESET button
(Page 33)".
With SINEC PNI
Follow the steps below to reset the device parameters to the factory settings with SINEC PNI:
1. Select the device whose parameters you want to reset.
2. Click "Reset device".
A dialog opens in which you can select one of the following options:
– Reset to PROFINET default settings
Resets the selected device to the respective default settings of the PROFINET IO profile.
The settings that are reset depend on the functional scope of the device. This function is
only available for devices that support the current PROFINET standard.
Note
Loss of the IP address
When the settings are reset to the default settings of a PROFINET IO profile, the IP address
is also lost. The device can then only be addressed via the serial interface, SINEC PNI or via
DHCP.
– Restore Factory Defaults
Resets the selected device to factory settings.
3. Confirm the selection with "OK".
During configuration
You will find detailed information on resetting the device parameters using the WBM and CLI in
the configuration manuals see also section "Introduction (Page 5)":
• SCALANCE XB-200/XP 200 Web Based Management, section "Restart"
• SCALANCE XB-200/XP-200 Command Line Interface, section "Reset and Defaults"
NOTICE
Cleaning the housing
Only clean the outer parts of the housing with a dry cloth.
Do not use any liquids or solvents.