Connecting up
6.10 Replacing the PLUG (C-PLUG or KEY-PLUG)
SCALANCE W786-x
56
Operating Instructions, 11/2014, A5E03678337-07
Removing the PLUG
Figure 6-9
Location of the PLUG slot with the housing cover removed
Follow the steps below to remove a PLUG from the device:
1.
Turn off the power to the device.
2.
Remove the housing cover, see section "Removing/fitting the housing cover".
3.
Insert a screwdriver between the front edge of the PLUG and the slot and release the
PLUG.
4.
Remove the PLUG from the slot.
5.
Screw the housing cover back onto the device.
Inserting the PLUG
Follow the steps below to insert a PLUG in the device:
1.
Turn off the power to the device.
2.
Remove the housing cover, see section "Removing/fitting the housing cover".
3.
The housing of the PLUG has a protruding ridge on the long side. The slot has a groove
at this position. Insert the PLUG correctly oriented into the slot. The PLUG is correctly
inserted when it is completely inside the device and does not jut out of the slot.
4.
Screw the housing cover back onto the device.