5.4.2.3
wlan ipcf protocol-support pnio (access point)
Note
This command is only available with the following KEY-PLUG:
● W740 iFeatures (MLFB 6GK5 907-4PA00)
Description
With this command, you enable the optimized support of PROFINET or Ethernet/IP.
Frames with the selected protocol are preferred.
Requirement
The SCALANCE W700 device is in access point mode.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan ipcf protocol-support {pnio | ethernet-ip}
Parameter
Description
Range of values / note
pnio
Keyword for the PROFI‐
NET
ethernet-ip
Keyword for the Ether‐
Net/IP
Result
The optimized support of PROFINET or Ethernet/IP is enabled.
Further notes
You disable the optimized support with the command.
You display the setting with the
show wlan ipcf
command.
Functions specific to SCALANCE
5.4 iPCF
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
126
Configuration Manual, 09/2017, C79000-G8976-C324-08