The parameter has the following meaning:
Parameter
Description
Range of values / note
wlan 0/X
WLAN interface
Enter a valid interface.
ms
The interval in milliseconds (ms) be‐
tween acquisition of two measured val‐
ues
100 - 60000
The first measured value is dis‐
played only after the set time interval
has elapsed.
sample_number
This parameter specifies how many
measured values will be recorded.
1 - 20000
bidirectional
The values are recorded by the access
point
Requirement
Firmware version > 6.1 is installed
on the access point.
Note
The access point sends its data to a
maximum of 3 clients on which sig‐
nal recorders are running. The ac‐
cess point data is not displayed on
other clients.
For information on identifiers of addresses and interfaces, refer to the section "The CLI
Result
The recording is configured and will be started. The measured values are output in the CLI
and logged in files. If these files already exist, they will be overwritten. If the set total number
of measured values is reached, the recording stops automatically.
Use the
wlan signal-recorder <wlan 0/X> stop
command to stop the recording early.
During the recording, it is possible that working in the CLI becomes slower.
Further notes
You stop the recording early with the
wlan signal-recorder <wlan 0/X> stop
command.
You display the status of the signal recorder and the recording with the
show wlan signal-
recorder <wlan 0/X>
command.
Functions specific to SCALANCE
5.3 Signal recorder
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
122
Configuration Manual, 09/2017, C79000-G8976-C324-08