Page 8
Pointek CLS500 – INSTRUCTION MANUAL
7ML19985GG03
mmmm
m
Specificat
ions
Process
Pressure rating
1
50 bar standard
Temperature rating
+200
C
+392
F
standard: max. +400
o
C (+752
o
F)
Approvals
CE
Complies with the following European Directives:
EMC Directive 2004/108/EC,
ATEX Directive 94/9/EC, and
PED Directive 97/23/EC
C-TICK
Dust Ignition Proof (DIP)
ATEX II 3GD (EEx nA [ib] IIC T4...T6)
FM/CSA:
Class I, Div. 2, Gr. A,B,C,D T4
Class II, Div. 1, Gr. E,F,G T4
Class III, Div. 1, Gr. E,F,G T4
Flame-proof/
ATEX II 1/2 GD (EEx d [ia] IIC T6...T1)
Explosion-proof enclosure
FM:
Class I, Div. 1, Gr. A,B,C,D T4
Lloyds Register of Shipping
Categories ENV1, ENV2, ENV3, ENV5
1.
Please refer to page 17, Temperature/ Pressure Curve chart, for specific
combinations of temperature and pressure.
Notes:
•
See
on page 100 for details of certification.
•
Intrinsically Safe (IS) approval [ATEX II 1 G (EEx ia IIC T4...T6),FM/CSA:Class I,
Div.1, Gr. A,B,C,D T4] no longer available. For CLS500 devices purchased prior to
June 2008 with IS approval, refer to Instruction Manual 7ML19985GG01,
Edition 1.0. Go to www.siemens.com/pointek. From the CLS500 product page,
search the Instructions and Manuals archive.
•
EMC testing was conducted on the CLS500 rod version while mounted in a
metallic vessel and wired using shielded cable, where the cable was terminated
in an EMC cable gland at the device entry point. In areas with high levels of EMI,
measurement deviations of up to ± 1% may be observed.