Extended Administration
84
Example System-wide configuration file
<?xml version = "1.0" encoding = "utf-8" ?>
- <Message>
<Action>WriteItems</Action>
<ItemList>
<Item name = "system-config-version">2005.07.19 05:39 GMT</Item>
<Item name = "admin-pwd">424242</Item>
<Item name = "system-description">Siemens Communications</Item>
<Item name = "dns-domain-name">ust.local</Item>
<Item name = "dns-server-addr">172.16.127.2</Item>
<Item name = "dns-server-addr2">172.16.127.3</Item>
<Item name = "port1">0</Item>
<Item name = "port2">0</Item>
<Item name = "reg-ttl">3600</Item>
<Item name = "registrar-addr">as.broadworks.net</Item>
<Item name = "reg-addr">as.broadworks.net</Item>
<Item name = "function-key-def" index = "6">31</Item>
<Item name = "function-key-def" index = "14">10</Item>
</ItemList>
</Message>
Device Specific File
Each device-specific configuration file will have a file name that includes
the phone's MAC address (e. g. "op410adv_conf001E300A9F3.xmll"),
which includes phone-specific parameters.
Example Device Specific File
<?xml version = "1.0" encoding = "utf-8" ?>
- <Message>
<Action>WriteItems</Action>
- <ItemList>
<Item name = "device-config-version">2005.07.19 06:09 GMT</Item>
<Item name = "e164">3015553005</Item>
<Item name = "sip-name">John Doe</Item>
<Item name = "register-by-name">false</Item>
<Item name = "line-sip-uri" index = "6">3015553009</Item>
<Item name = "line-primary" index = "6">true</Item>
<Item name = "line-hunt-sequence" index = "6">1</Item>
<Item name = "line-shared-type" index = "6">0</Item>
<Item name = "line-sip-realm" index = "6">as.broadworks.net</Item>
<Item name = "line-sip-user-id" index = "6">3015553009</Item>
<Item name
=
"line-sip-pwd" index = "6">0dskmwefd</Item>
</ItemList>
</Message>
Detailed example configuration files und informations you will find
in the "XML Configuration Management" Administrator Manual .
Summary of Contents for optiPoint 420 economy
Page 1: ...HiPath 8000 Sylantro Broadsoft optiPoint 410 S V6 0 optiPoint 420 S V6 0 Administrator Manual ...
Page 114: ...Web Interface 114 Network IP and routing Network Addresses page 57 ...
Page 115: ...Web Interface 115 SIP environment Configure System Information page 60 ...
Page 116: ...Web Interface 116 SIP features SIP Features page 63 Transfer on Ringing ...
Page 117: ...Web Interface 117 Quality of Service Quality of Service QoS page 58 ...
Page 120: ...Web Interface 120 Time and date Configuring Date and Time page 66 ...
Page 121: ...Web Interface 121 SNMP Use SNMP page 91 Speech Change Speech Parameters page 92 ...
Page 122: ...Web Interface 122 Ringer settings Configure Ringer Settings page 93 ...
Page 124: ...Web Interface 124 Function keys Function Key assignments page 73 ...
Page 126: ...Web Interface 126 Function key Select a function optiPoint 410 420 economy economy plus ...
Page 128: ...Web Interface 128 Function key Line key optiPoint 410 420 advance standard Multiline page 67 ...
Page 137: ...Web Interface 137 Address Book Address Book page 162 WAP WAP Settings page 80 ...
Page 141: ...Web Interface 141 RTP Statistics These parameters are used for development only ...
Page 142: ...Web Interface 142 QoS Data Collection These parameters are used for development only ...
Page 146: ...Web Interface 146 FPN Port Settings Only available in Web Interface ...