BA 5230 en 04/2011
7.
Startup
Observe the instructions in section 3, "Safety instructions"!
The gear unit must not be started up, if the required instructions are not available.
7.1
Procedure before startup
7.1.1
Removal of preservative agent
The location of the oildraining points is marked by an appropriate symbol on the dimensioned drawing in
the gearunit documentation.
Before restarting the gear unit the screw plug (if fitted) must be replaced with the
breather screw or the air filter.
Oildraining point:
•
Place suitable containers under the oildraining points.
•
Unscrew the oildrain plug or open the oildrain cock.
•
Remove remaining preservative agent and/or runningin oil from the gear unit using a suitable
container.
─ Unscrew any existing residualoildrain plugs.
•
Dispose of remaining preservative agent and/or runningin oil in accordance with regulations.
Any oil spillage must be removed immediately with an oilbinding agent.
The oil must not come into contact with the skin (e.g. the operator’s hands).
The safety notes on the data sheets for the oil used must be observed here!
•
Screw in the oildrain plug or reclose the oildrain cock.
•
Screw in any unscrewed residualoildrain plugs again.
2
4
3
1
Fig. 22:
Oil inlet and oil drain on the gear unit
1
Breather
3
Oillevel indicator
2
Oil inlet
4
Oil drain
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.