BA 5230 en 04/2011
6.8
Gear unit with cooling coil
•
Before connecting the cooling coil the screw plugs must be removed from the connecting bushes.
•
Flush the cooling coil (in order to remove any contamination).
•
Connect the coolingwater in and outflow pipes (for exact position of the connections, see
dimensioned drawing).
Observe also item 5.7.2.
6.9
Gear unit with addon air oilcooler
•
Wire the fan motor electrically.
•
Wire pressure monitor electrically.
Observe also item 5.7.3.
6.10
Gear unit with addon water oilcooler
•
Before connecting the water oilcooler remove the sockets from the coolingwater connections.
•
Flush the water oilcooler (in order to remove any contamination).
•
Connect the coolingwater in and outflow pipes (for flow direction and exact position of connections,
see dimensioned drawing).
Make sure when installing the pipework that no forces, moments or vibrations act
upon the connections of the water oilcooler.
•
Wire the pressure monitor electrically (in case of gear units with corresponding equipment only).
Observe also item 5.7.4.
6.11
Gear unit with separate oilsupply system
•
Remove the sockets and/or flanges from the suction and delivery lines prior to connecting the system.
•
Fit the system to the gear unit or install it separately in accordance with the drawings supplied in the
gearunit documentation.
•
The pipework must not be overstressed during the fitting procedure.
•
For the exact position and size of the connections points of the pressure and suction lines refer to the
illustration of the gear unit on the drawings in the gearunit documentation.
6.12
Gear unit with heating
•
Wire the heating system electrically.
6.13
Gear unit with oiltemperature monitoring system
•
Wire the resistance thermometer with evaluating instrument (to be provided by customer) electrically.
6.14
Bearingmonitoring system
•
Wire the resistance thermometer with evaluating device electrically (in case of a configuration as
described in item 5.13). The evaluating device must be provided by the customer.
6.15
General notes on addon components
For operating and servicing the components described in section 6, the pertinent instructions
manuals and the specifications in section 5 must be observed.
For technical data, refer to the data sheet and/or the list of equipment.