7.4 Safety-minded Work
•
The qualified staff referred to in Section 7.3 are responsible for job safety.
•
The ELP 319 end position detector may only be operated if it is in perfect working order.
•
The work must be carried out in such a way that human safety is not diminished nor the
operation of the ELP 319 end position detector impaired.
•
As a rule, safety equipment must not be removed or put out of operation.
•
Safety-minded work implies that staff are to be informed of incorrect actions and any faults
detected are to be reported to the authority or person responsible.
DANGER
No unauthorised modifications to the ELP 319 end position
detector are to be carried out.
7.5 Agents
The following detergents, lubricants and other agents are used for the ELP 319 end position detector:
Designation
Application
•
White spirit
Cleaning of parts
•
Molub-Alloy 243 Arktic grease
Greasing of parts
•
SAE 10 W/40 oil (do not use spray oils
containing turpentine or silicone)
Oiling of parts
•
Flake graphite
Grase Cover lock
•
De-icing agent
De-ice Cover lock
CAUTION
Prevent your skin from coming into contact with the above-
mentioned agents, in particular the grease! They (especially
grease) can irritate the skin or cause other allergic reactions. Only
apply them using gloves and appropriate tools (e.g. a brush).
7.6 Earthing of the Detector Housing
The detector housing must be connected to earth potential or, on electrified lines, to the railway
earthing system. For this purpose, use insulated copper wire-rope cable with the cross section
specified by the railway operator. Connect this earthing cable to the M16 earthing terminal of the
housing using a cable lug.