10.3 Mounting the Detector Rods
The ELP 319 end position detector has two parallel, freely movable detector slides. Mounting
examples of connections of the detector rods with the ELP 319 end position detector (see Figure 11):
•
on single points in conjunction with point machines (see Figure 11, above)
•
on type S49-1200 single points for detecting the second clamp point lock (see Figure
11, centre)
•
on spring return points with return springs (here the short detector rod is generally
mounted to the tip of the open point blade, see Figure 11, below)
NOTE
The two detector rods are to be mounted to the two point blades
and the detector slides.
The detector rods must be adjusted to match the stroke of the
points. For this, turn the hexagon nuts on the threaded section of
the detector rods forwards or backwards.
The version of the detector rods depends on the point locks used.