9.2 Circuit Diagrams
The circuit diagrams below show standard internal wirings of the ELP 319 end position detector.
Other wiring variants are available on request.
Contact position shown
corresponds to:
Rightmost position
of points for
left-hand mounting
Closed point blade
1
2
B
1B
1A
4A 4B
2B
2A
1
2
C
3 4
B
4 3
C
3B
3A
B
1
3
2 4 gy
bu
rd
bu
C
1
3
2 4
gy
bn
rd
bn
A
1
B
1
A
2
B
2
A
3
B
3
A
4
B
4
rd
rd
gy
gy
bn
bn
bu
bu
Open point blade
Leftmost position
of points for
right-hand mounting
Figure 7
Circuit diagram of the ELP 319 end position detector
(variant with eight series terminals)