12.4.4 Removing the Detector Slides
Check the easy movement of the detector slides with the end position detector detached. The
detector slides must be easy to move from one end position to the other by pulling or pushing them
with one hand.
The detector slides 1 (see Figure 19) with guide sleeve 3 must be exchanged in the event of the
following:
•
sluggish movement of the detector slides
•
worn-out guides in the guide sleeve
•
leakiness of the guide sleeve
1
Detector slides
2
Guide plate
3
Guide sleeve
4
Fastening bolts
Figure 19
Removing the detector slides
Before removing the detector slides 1, remove the contact arrangements and guide plate 2 (see
Figure 19). Then, undo the fastening bolts 4. Swing the detector slides 1 up to remove them from the
housing of the end position detector. For assembling the detector slides 1, mount all components by
carrying out the same steps in reverse. Perform a functional check as described in Section 12.5 .
1
4
2
3