12.4.3 Exchanging the Contact Arrangements
Both the movable and the fixed contact arrangement must be exchanged each time the ELP 319 end
position detector is repaired (see Figure 18).
For removing contact arrangements 2 and 4, remove the fastening bolts 1 and unscrew the wiring 3.
For fitting the contact arrangements, carry out the same steps in reverse. Adjust distance A as
described in Section 10.5 . Once the work has been completed, put the hoods on the sets of contacts
again.
A
Distance
1
Fastening bolts
2
Movable contact arrangement
3
Wiring
4
Fixed contact arrangement
Figure 18
Exchanging the contact arrangements