10.4 Linking the Detector Slides
The detector slides are linked to the detector rods using insulated fork heads (see Figure 12).
Insulating sleeves
Figure 12
Detector slide with insulated fork head
10.5 Adjusting the Detector Slides
The detector slide stroke of the ELP 319 end position detector can be continuously adjusted from
30 mm to 190 mm.
Since the mounting and fitting dimensions are identical, the ELP 319 end position detector can be
mounted on the same base plates and using the same rodding as the Bsg.ktr.26 point detector (see
Figure 13). The ELP 319 end position detector replaces all models of the Bsg.ktr.26 point detector.
Detector rod
Figure 13
Trackside arrangement of the ELP 319 end position detector