ECO REFERENCE MANUAL
10-8
Output Relays (RL1 and RL2)
max. 0.8 A/230V AC
(Overvoltage cat.2)
2.0 A/30 V DC
(resistive rating)
21
22
23
24
25
26
27
RL2B
(NO)
RL2C
(COM)
P5V+
N-
N-
P+
PE
Analog Output 2
0/4 ....20 mA
(500
Ω
load)
use with terminal 13
RS485
(for USS protocol)
MIDIMASTER Eco
RANGE
A2OUT+
Front Panel
RS485 D-type
5
9
1
6
OV
P+
PE (case)
N-
5V (max. 250mA)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
20
19
P10+
0V
AIN+ AIN-
DIN1
DIN2 DIN3 DIN4 P15+ PIDIN+ PIDIN-
AOUT- PTC
PTC
DIN5 DIN6
Power Supply
(+10 V, max. 10mA)
Analog Input 1
-10 V to +10 V
0/2
....
10V
(input impedance 70k
Ω
)
or
0/4
....
20mA
(Resistance = 300
Ω
)
Digital Inputs
(7.5....33 V, max. 5mA)
Power Supply
for PID Feedback
Transducer
(+15V, max. 50mA)
Analog input2
0
....
10 V
or
0
....
20mA
Micromaster
Analog Output
Midimaster
Analog Output 1
0/4....20 mA
(500
Ω
load)
Motor temp.
protection input
Note: For PTC motor thermal
protection, P087 = 1
Digital Inputs
(7.5 ....33 V, max 5mA)
RL1A
(NC)
RL1B
(NO)
RL1C
(COM)
Output Relays (RL1 and RL2)
max. 0.8 A/230V AC
(Overvoltage cat.2)
2.0 A / 30 V DC
(resistive rating)
21
22
23
24
25
26
RL2B
(NO)
RL2C
(COM)
P5V+
N-
N-
P+
PE
RS485
(for USS protocol)
MICROMASTER Eco
RANGE
MIDIMASTER A1 OUT+
MICROMASTER A OUT+
Control Connections