Approvals
C.1 Antennas
CP 1242-7 V2
Operating Instructions, 05/2014, C79000-G8976-C311-00
59
ATEX approval
ATEX approval: II 3 G Ex nA II T4
Test number: KEMA 10 ATEX 0166X
EN 60079-0:2006: Potentially explosive atmosphere - general requirements
EN 60079-15:2005: Electrical apparatus for explosive gas atmospheres; type of protection 'n'
Over and above this, the following conditions must be met for the safe deployment of the CP:
Install the modules in a suitable enclosure with degree of protection of at least IP54 to
EN 60529 and take into account the environmental conditions for operation of the
devices.
If the rated temperatures of 70°C at the cable entry or 80°C at the branching point of the
wires are exceeded, the permitted temperature range of the selected cable must be
suitable for the actual measured temperatures.
Measures must be taken to prevent the rated voltage being exceeded by more than 40%
due to transient disturbances.
C-Tick approval
The CP meets the requirements of the AS/NZS 2064 standards (Class A)
Anatel approval
“Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar
interferência a sistemas operando em caráter primário.”
Canada approval
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout