Connect external components
Desk call station extension PTO2001-A1
7
134 | 173
A6V10430579_en--_b
7.2.5 Configuration
The RS232 communication requires proper ID settings of all PTO2001-A1.
Usually the PT2001-A1 are delivered with correct pre-configured ID settings of the
connected PTO2001-A1.
Fig. 91: PTO2001-A1 keypad numbering
7.2.6 Check the ID settings
Follow the steps below to check the ID settings:
1.
Disconnect the 24 V power supply from the PTO2001-A1.
2.
Press and hold the keypads 00 and 11 on the PTO2001-A1.
3.
Connect the 24 V power supply to PTO2001-A1.
The PTO2001-A1 switches to the configuration mode with a LED lamp test:
red/green/yellow LEDs are activated.
Afterwards the ID is indicated with a green blinking LED (refer to the table
below).
4.
Perform a power reset with a disconnecting and re-connecting of the 24 V
power supply to switch to the normal mode.
Green blinking keypad
00
01
02
03
ID of PTO2001-A1
ID1
ID2
ID3
ID4