
5.6
SCALANCE X204RNA EEC interfaces
5.6.1
TP interfaces
Connector pinout
On the SCALANCE X204RNA EEC (PRP and HSR), the TP interfaces are implemented as RJ-45 jacks
with the MDI-X assignment (Medium Dependent Interface Autocrossover) of a network
component.
Figure 5-7
RJ-45 jack
Table 5-3
Pin assignment
Pin number
Assignment
Pin 8
n. c.
Pin 7
n. c.
Pin 6
TD-
Pin 5
n. c.
Pin 4
n. c.
Pin 3
TD+
Pin 2
RD-
Pin 1
RD+
Note
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP port.
With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of up to 100 m is permitted
between two devices depending on the cable type.
Note
The interfaces of the SCALANCE X204RNA EEC (PRP and HSR and PRP/HSR) meet the
requirements for environment B according to IEEE 802.3, section 33.4.1.1.
Device description
5.6 SCALANCE X204RNA EEC interfaces
SCALANCE X-200RNA
42
Operating Instructions, 04/2022, C79000-G8976-C342-07