Agent Enabled Features
• "TELNET"
Here, you specify whether or not an unencrypted connection using TELNET can be
established.
• "SSH"
Here, you specify whether or not an encrypted connection using SSH can be established.
• "HTTPS only"
Here, you specify whether or not the WBM can only be reached via an SSL encrypted
connection.
• "E-Mail"
Here, you specify whether or not events are sent to an e-mail address.
• "Syslog"
Here, you specify whether or not events are sent to a Syslog server.
• "SNTP"
Enables / disables synchronization of the IE switch system time using an SNTP server in the
network.
• "DHCP"
Here, you specify whether or not the IP address can be obtained using the Dynamic Host
Configuration Protocol.
• "BOOTP"
Here, you specify whether the IP address can be obtained using the Bootstrap Protocol.
• "DCP"
If you select this option, the device can be accessed and configured using DCP (SINEC PNI and
STEP 7).
• "DCP Read Only"
If you select this option, the configuration data can only be read via DCP (SINEC PNI and STEP
7).
Agent IP Configuration
• "IP Address"
Enter the IP address of the SCALANCE X-200RNA here.
• "Subnet Mask"
Enter the subnet mask of the SCALANCE X-200RNA here.
• "Default Gateway"
If you require the IE switch to communicate with devices (diagnostics stations, E-mail
servers, etc.) in a different subnet, you will need to enter the IP address of the default gateway
here.
• "MAC Address"
The MAC address of the SCALANCE X-200RNA.
Functional description and configuration using Web Based Management
9.9 The "Agent" menu
SCALANCE X-200RNA
116
Operating Instructions, 04/2022, C79000-G8976-C342-07