5.2
Product overview
Article numbers of the IE switches SCALANCE X-200RNA
The IE switches SCALANCE X-200RNA are available in different versions. These are listed in the
table below for a better overview:
Device
Article number
Supported modes
SCALANCE X204RNA (PRP)
6GK5204-0BA00-2KB2
PRP ↔ standard Ethernet
PRP ↔ HSR link
SCALANCE X204RNA (HSR)
6GK5204-0BA00-2MB2
HSR ↔ standard Ethernet;
HSR ↔ PRP link
SCALANCE X204RNA EEC (PRP)
6GK5204-0BS00-3LA3
PRP ↔ standard Ethernet
SCALANCE X204RNA EEC (HSR)
6GK5204-0BS00-2NA3
HSR ↔ standard Ethernet;
HSR ↔ PRP link
SCALANCE X204RNA EEC (PRP/
HSR)
6GK5204-0BS00-3PA3
PRP ↔ standard Ethernet;
HSR ↔ standard Ethernet;
HSR ↔ PRP link
Unpacking and checking
WARNING
Do not use any parts that show evidence of damage
If you use damaged parts, there is no guarantee that the device will function according to the
specification.
If you use damaged parts, this can lead to the following problems:
• Injury to persons
• Loss of the approvals
• Violation of the EMC regulations
• Damage to the device and other components
Use only undamaged parts.
1. Make sure that the package is complete.
2. Check all the parts for transport damage.
Scope of delivery
The following components are supplied with the SCALANCE X204RNA:
• SCALANCE X204RNA device
• 2-pin plug-in terminal block (signaling contact)
• 4-pin plug-in terminal block (redundant power supply)
Device description
5.2 Product overview
SCALANCE X-200RNA
Operating Instructions, 04/2022, C79000-G8976-C342-07
33