9.10.5
LLDP Configuration
In the "LLDP Configuration" dialog box, you enable/disable the forwarding of received LLDP
frames for the device.
Figure 9-41
Supervision Frames
If the option is enabled, the device forwards LLDP frames like standard multicast frames.
If the option is disabled, the device discards all received LLDP frames.
9.10.6
The "Statistics" Menu
Counting and evaluation of received frames
A SCALANCE X-204RNA has internal statistics counters with which it counts the number of
received frames for each port according to the following criteria:
• Frame length
• Message frame type
• Bad frames
This information provides you with an overview of the data traffic and any problems on the
network.
Functional description and configuration using Web Based Management
9.10 The "Switch" menu
SCALANCE X-200RNA
Operating Instructions, 04/2022, C79000-G8976-C342-07
139