Examples
Via the “cursor left” and “cursor right” keys, you can display other actual parameters,
e.g. reference current (object 99), digital inputs and outputs (objects 106 and 107),
analog inputs (objects 310 and 315), analog outputs (objects 329 and 331) and the
warning register (object 87):
Displayed unit of the current:
▶
Up to software version (operating terminal) 3.18: The displayed unit of the current
depends on the DeviceDriveFunctionMode: In the modes “Servo” and “HSBLOCK”,
the current is displayed as sine wave peak amplitude (A), in the modes “HSPWM”
and “HSPAM / V/f”, it is displayed as RMS value (Arms).
▶
Software version (operating terminal) 3.19 and higher: The displayed unit of the cur-
rent depends on the DeviceDriveFunctionMode: In the mode “HSBLOCK”, the cur-
rent is displayed as sine wave peak amplitude (A), in the modes “Servo”, “HSPWM”
and “HSPAM / V/f”, it is displayed as RMS value (Arms).
In “HSPAM / U/f” operation, the active output stage power (object 390) in kW is dis-
played:
With software version (operating terminal) 3.12 and Odict version 19 and higher, for
the V/f control, the active current (object 430) is displayed instead of the reference cur-
rent. In addition, the actual apparent current (object 431) and the actual motor voltage
(object 434) are displayed for this drive function.