9
Switch Cabinet Installation
The operating terminal 0362153 is designed to be mounted to a switch cabinet. The
mounting instructions and a mounting template can be found in the technical information
“TIE_OperatingTerminal_0362153_Mounting.pdf”.
By means of the switch cabinet kit 32299567, the operating terminal 0362150 can also
be mounted to a switch cabinet. The mounting instructions can be found in the technical
information “TIE_MountingPlate_OperatingUnit_0362150.pdf”.
Instead of the supplied extension cable, you can also use your own cable suitable in
length.
Extension Cable
▶
shielded round cable
▶
9-pole male D-sub connector ↔ 9-pole female D-sub connector
Pin assignment on the device
▶
9-pole female D-sub connector ↔ 9-pole male D-sub connector
▶
1:1 pin assignment
Operating terminal: X62
Drive: COM1 connector
Pin
I/O
Name
I/O
Pin
1
E
VCC5 (5 V voltage supply)
A
1
2
A
SD-TX1 (transmit data to drive)
E
2
3
E
SD-RX1 (receive date from drive)
A
3
4
I/O
CAN_L
I/O
4
5
I/O
GND (ground)
I/O
5
6
E
SD-RX2 (receive date from drive)
A
6
7
A
SD-TX2 (transmit data to drive)
E
7
8
I/O
CAN_H
I/O
8
9
I/O
GND (ground)
I/O
9
Connec-
tor shell
Cable shield
Connec-
tor shell
Stud bolt flange: max. tightening torque = 0.7 Nm
Trouble-free operation is provided up to at least 3 m cable length, when the conductor
cross-section is 0.14 mm².
It is possible to operate the terminal with a cable length of >3 m to 15 m. But external
interferences may cause malfunction of the operating terminal/drive. Trouble-free func-
tion of the devices must be assured by the machine manufacturer.
SIEB & MEYER recommends a separate voltage supply for this purpose. If a larger dis-
tance must be covered, you can connect a separate voltage source to the operating ter-
minal.