Functions of the Terminal
Via the “Cursor Left” and “Cursor Right” keys, you can show additional actual pa-
rameters, e.g. the power (object 324), the digital inputs and outputs (objects 106
and 107), the analog inputs (objects 310 and 315), the analog outputs (objects 329
and 331) and the warning register (object 87):
In case of an error, the actual error (object 69) is displayed as error text with the corre-
sponding error number. A latched error (object 70) is displayed with the error number. In
case of a warning in the warning register (object 87), the warning code will be displayed.
14.2.1.2
Actual Value Display of Devices without USB Support
In automatic operation, the actual values of the drive are displayed on the terminal.
1st display line
Output stage off:
The name of the current spindle (object 22) is displayed.
Output stage on:
The actual speed (object 168 up to Odict version 7, object 398 with Odict version 8
and higher) is displayed.
2nd display line
Output stage off:
The set reference speed (object 168 up to Odict version 7, object 395 with Odict
version 8 and higher) is displayed.
Output stage on:
The set reference speed value is displayed. This value depends on the Odict version
and the software version of the operating terminal:
▶
Up to software version (operating terminal) 3.09: object 168 up to Odict
version 7, object 395 from Odict version 8.
▶
Software version (operating terminal) 3.10 and higher: object 168 up to Odict
version 7, object 396 from Odict version 8.
▶
Software version (operating terminal) 3.17 and Odict version 8 or higher:
– For device status “Switched on”, object 395 is displayed
– For device status “Operation enabled”, object 396 is displayed
3rd display line
The status of the finite state automaton is displayed.
If the drive status is “Operation enabled”, a progress bar for the load (object 324 for Odict
version 8 and higher) on the parameterized rated motor current is displayed in %.
26
Drive System SD2x - Operating Terminal 0362150 and 0362153