Functions of the Terminal
With software version (operating terminal) 4.02 and higher, the motor temperature (ob-
ject 63) is displayed if you have parametrized a KTY sensor or a PT1000 sensor for
the temperature monitoring. Otherwise, a corresponding note will be displayed.
Errors, warnings and event messages
In the event of an error, the current error (object 69) or the latched error (object 70)
with the corresponding error code will be displayed. With software version (operating
terminal) 3.20 and higher plus Odict version 17 and higher, the terminal will display an
additional sub error code (object 425), if available.
If there is a warning in the warning register (object 87), the corresponding warning code
will be displayed.
If there is information on the cause of the quick stop (object 71) available, the quick stop
code will be displayed. Top priority is given to the error display.
14.2.2
LED Display
The LED displays have the following meaning in AUTOMATIC MODE:
▶
The LED M0 illuminates when the drive signals “speed zero” in the status word (ob-
ject 67).
▶
The LED M1 illuminates when the drive signals “speed reached ” in the status word
(object 67). meldet.
▶
If an error is returned, both LEDs flash alternately.
14.2.3
Controlling the Drive
In order to control the drive via the operating terminal, you must set the parameters of
the drive as follows:
▶
Control channel: Serial interface / RS485 / USB
▶
Setpoint channel:
– Up to software version (operating terminal) 3.08: Serial interface / RS485 / USB
– Software version (operating terminal) 3.09 and higher: The selected setpoint
channel must support the used parameters.
28