PJC 221 & 222
Alarm System
EN
MC_0101
STOP
front s_v strek_PJC222.pdf 1 04.11.2010 11:05:34
(Button below this symbol
pressed)
No. of alarms
Alarm description
Reset alarm
and Return
Use joystick to scroll if
more than two alarms
Scroll bar
Name and
location of
device
Refer to Alarm code overview/table on pages 23-24
for full description on the diff erent alarm codes.
Example PJC 222:
When there is an alarm or a fault, the panel will show this alarm situation by changing LCD display backlight to red color.
The panel will also change to show “Alarm Info” on the bottom of the screen, indicating that by pressing the corresponding button
below, you will get information about what the problem is (examples below).
Entering “Alarm Info” menu will silence the alarm on all PJC221 and PJC222 panels.
Some alarms needs an reset to stop alerting.
Auto Reset
Some alarms are automatically reset when the fault is no longer present.
This means that this alarms don’t need an manual reset action to be removed from the panel display and the audible alert to stop. At ‘Alarm De-
scription’ pages in the “Auto Reset” column you can see which alarms that are auto reset.
SPECIFIC ALARMS
STOP BUTTON
Pressing the STOP button on a hydraulic panel will activate the dump valve and all hydraulic consumers will
be disabled.
(NB: FOR EMERGENCY USE ONLY)
Panel will not run thrusters.
Pressing button below
will mute buzzer alarm at all panels and show the alarm info screen.
ALARM SHOWN ON INACTIVE PANELS!
This screen will be shown when any warning/alarm occures.
Pressing button below
will mute buzzer alarm at all panels and show the alarm info screen.
WARNING! HIGH SPEED. STABILIZER NOT ACTIVE!
(Only for yachts equipped with a Side-Power Stabilizer system) Warning will show when yacht is driven at
high
speed with stabilizer system inactive. Please refer to the Stabilizer ECU manual for speed settings.
Pressing button below
will mute buzzer alarm at all panels and show the alarm info screen.
Alarm code
SAC Power Managemant Status
EN
MC_0101
Symbol alternating with AC motor symbol every 1sec.
*For detailed information on SAC power management operation see SAC user manual.
Power Not Available
Power Management System
is preventing the thruster
from operating.
Reduced Power Mode
Thruster output is limited to
50 % thrust by Power Man-
agement System.
Menu System - Panel Setup
EN
MC_0101
PANEL
•
Move between parameters with the (stern) joystick.
•
Press the button below
to return to the previous menu.
•
Press the button below
to edit the selected parameter.
•
Parameter value will start to blink, use joystick to alter value.
•
Press the button below
to save the edited parameter.
•
Press the button below
to cancel editing without saving.
SYSTEM PANEL
BACKLIGHT LEVEL
Values: 1-5
Set level of panel backlight in daylight mode.
1 is lowest intensity, 5 is the highest.
BACKLIGHT NIGHT COLOR
Values: GREEN, BLUE, RED, WHITE
Select color of backlight in nightlight mode.
BACKLIGHT NIGHT LEVEL
Values: 1-3
Set level of panel backlight in daylight mode, 1 is lowest intensity, 3 is the highest.
TIMER AUTO-OFF
Values: OFF, 01-60 min
Set the time from last use to auto panel shutdown. Set from 1-60 minutes in 5 minute steps (1 minute steps from
1 to 5 minutes) or OFF (panel will not turn off automatically). Values when retract on the boat: 1-30 min.
UNIT TEMPERATURE
Values: CELSIUS (Default), FAHRENHEIT
Set the panel temperature displaying unit.
WHEN RETRACT IS OUT
Values: NO WARNING (Default), WARNING EVERY 10sec
Select ‘WARNING EVERY 10sec’ for external buzzer or lamp warning every 10 seconds when retract is out. This
will activate the internal relay for 0.2 seconds every 10 seconds while the retract is out. See page 26 for buzzer
connections.
RELAY OUTPUT
Values: ALERT LEVEL 1 , ALERT LEVEL 2 , ALERT LEVEL 3 (Default)
ALERT LEVEL 1: When using the HOLD Function the relay output warns if the motor temperature is getting
high or if the voltage is getting low.
ALERT LEVEL 2: The relay output warns for all alarms and warnings in the S-link system only when any device
is sending thrust. Even when the panel is turned OFF.
ALERT LEVEL 3: The relay output warns for all alarms and warnings in the S-link system. Even when the panel
is turned OFF.
See ‘Alarm descriptions’ in “Ext. buzzer activation at Alert Level” column for specifi c alarm action.
PANEL FACING
Values: FORWARD (Default), AFT
FORWARD: Is when panel is facing forward
AFT:
Is when panel is facing aft. Display view will rotate 180 degree and joysticks thruster function
will also rotate 180 degree.