 17

3059

10

2019

-

PJC 221 & 222

Alarm System

EN

MC_0101

STOP

front s_v strek_PJC222.pdf   1   04.11.2010   11:05:34

(Button below this symbol 

pressed)

No. of alarms

Alarm description

Reset alarm 

and Return

Use joystick to scroll if 

more than two alarms

Scroll bar

Name and 

location of 

device

Refer to Alarm code overview/table on pages 23-24 

for full description on the diff erent alarm codes.

Example PJC 222:

When there is an alarm or a fault, the panel will show this alarm situation by changing LCD display backlight to red color.

The panel will also change to show “Alarm Info”                   on the bottom of the screen, indicating that by pressing the corresponding button 

below, you will get information about what the problem is (examples below).

Entering “Alarm Info” menu will silence the alarm on all PJC221 and PJC222 panels.

Some alarms needs an reset to stop alerting.

Auto Reset 

Some alarms are automatically reset when the fault is no longer present.

This means that this alarms don’t need an manual reset action to be removed from the panel display and the audible alert to stop. At ‘Alarm De-

scription’ pages in the “Auto Reset” column you can see which alarms that are auto reset.

SPECIFIC ALARMS

STOP BUTTON

Pressing the STOP button on a hydraulic panel will activate the dump valve and all hydraulic consumers will 

be disabled.

(NB: FOR EMERGENCY USE ONLY) 

Panel will not run thrusters.
Pressing button below 

 will mute buzzer alarm at all panels and show the alarm info screen.

ALARM SHOWN ON INACTIVE PANELS!

This screen will be shown when any warning/alarm occures.

Pressing button below 

 will mute buzzer alarm at all panels and show the alarm info screen.

WARNING! HIGH SPEED. STABILIZER NOT ACTIVE! 

(Only for yachts equipped with a Side-Power Stabilizer system) Warning will show when yacht is driven at 

high 

speed with stabilizer system inactive.  Please refer to the Stabilizer ECU manual for speed settings.

Pressing button below 

 will mute buzzer alarm at all panels and show the alarm info screen.

Alarm code

SAC Power Managemant Status

EN

MC_0101

Symbol alternating with AC motor symbol every 1sec.

*For detailed information on SAC power management operation see SAC user manual.

Power Not Available

Power Management System 

is preventing the thruster 

from operating.

Reduced Power Mode

Thruster output is limited to 

50 % thrust by Power Man-

agement System.

Menu System - Panel Setup

EN

MC_0101

PANEL

• 

Move between parameters with the (stern) joystick.

• 

Press the button below 

 to return to the previous menu.

• 

Press the button below 

 to edit the selected parameter.

• 

Parameter value will start to blink, use joystick to alter value. 

• 

Press the button below 

 to save the edited parameter.

• 

Press the button below 

 to cancel editing without saving.

SYSTEM PANEL

BACKLIGHT LEVEL

Values: 1-5

Set level of panel backlight in daylight mode. 

1 is lowest intensity, 5 is the highest.

BACKLIGHT NIGHT COLOR

Values: GREEN, BLUE, RED, WHITE

Select color of backlight in nightlight mode.

BACKLIGHT NIGHT LEVEL

Values: 1-3

Set level of panel backlight in daylight mode, 1 is lowest intensity, 3 is the highest.

TIMER AUTO-OFF

Values: OFF, 01-60 min

Set the time from last use to auto panel shutdown. Set from 1-60 minutes in 5 minute steps (1 minute steps from 

1 to 5 minutes) or OFF (panel will not turn off  automatically). Values when retract on the boat: 1-30 min.

UNIT TEMPERATURE

Values: CELSIUS (Default), FAHRENHEIT

Set the panel temperature displaying unit.

WHEN RETRACT IS OUT

Values: NO WARNING (Default), WARNING EVERY 10sec

Select ‘WARNING EVERY 10sec’ for external buzzer or lamp warning every 10 seconds when retract is out. This 

will activate the internal relay for 0.2 seconds every 10 seconds while the retract is out. See page 26 for buzzer 

connections.

RELAY OUTPUT

Values: ALERT LEVEL 1 , ALERT LEVEL 2 , ALERT LEVEL 3 (Default)

ALERT LEVEL 1:   When using the HOLD Function the relay output warns if the motor temperature is getting    

 

 

 

  high or if the voltage is getting low. 

ALERT LEVEL 2:   The relay output warns for all alarms and warnings in the S-link system only when any device  

 

 

 

  is sending thrust. Even when the panel is turned OFF.

ALERT LEVEL 3:   The relay output warns for all alarms and warnings in the S-link system. Even when the panel  

 

 

 

  is turned OFF.

 

See ‘Alarm descriptions’ in “Ext. buzzer activation at Alert Level” column for specifi c alarm action.

PANEL FACING

Values: FORWARD (Default), AFT

FORWARD:     Is when panel is facing forward

AFT:  

 

  Is when panel is facing aft. Display view will rotate 180 degree and joysticks thruster function  

 

 

 

  will also rotate 180 degree.

Summary of Contents for S-linkControl Panel PJC221

Page 1: ...SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway www side power com Document id Revision Date 3059 10 Control Panels PJC 221 PJC 222 To download your language go to www side power com K e e p t...

Page 2: ...System PDC 101 Setup 10 AC System PDC 201 Setup 10 AC System PDC 301 Setup 11 DC System Automatic Main Switch Setup 12 DC System PPC SR150000 SR61242 Setup 12 DC System RCRS 1 RCRS 2 Setup 13 DC Syste...

Page 3: ...ing to international or special national regulations Instructions in this guide cannot be guaranteed to comply with global electric mechanic regulations classification rules It is the installers respo...

Page 4: ...he direction of the arrows at select ed power Press for more and for less power 6 steps If any control unit are running the thruster in opposite direction to the hold function the hold function will b...

Page 5: ...EN 60533 Weight 215 gr Description Minimum Maximum Units Comment Input voltage 9 31 Volt DC Powered from S Link Current Voltage 20 120 mA External Alarm Buzzer Voltage 31 Volt DC External Alarm Buzzz...

Page 6: ...222 Supply 12V 24V DC S link External alarm buzzer 12V 24V DC max 0 5A Internal fuse relay External alarm buzzer connection Rear side of panel Connections for optional external buzzer audible alarm C...

Page 7: ...s can not be operated to auto setup is completed OR RUN SETUP DEVICES IN CONFLICT Detected devices in con ict Two or more thrusters defined as same instance bow stern bow STB Stern STB Run Setup proce...

Page 8: ...lve Pump Control will then not be able to edit NB Pump Control Auto must only be used on PHC 024 with rmware V 1 008 or higher Cooling Pump Values Always Running Temp Controlled default When the optio...

Page 9: ...o protect the thruster during deceleration and will close while thruster is running By selecting with Bypass Valve you activate this signal and addition change ramp parameters to match this setup All...

Page 10: ...display and thruster s at the right side of the display Direction Values NA Not Available AC System PDC 101 Setup AC System PDC 201 Setup EN EN MC_0096 MC_0096 PDC 201 Location Values BOW STERN BOW ST...

Page 11: ...uster location should be set as BOW STB or STERN STB This so the hydraulic controller are shown at the left side in display and thruster s at the right side of the display Direction Values Normal defa...

Page 12: ...his so the hydraulic controller are shown at the left side in display and thruster s at the right side of the display Direction Values Normal default Inverted Switches between Normal and Inverted runn...

Page 13: ...t sideways when both thrusters are operated simultanously with input from the remote only MSI8730 Location Values BOW STERN BOW STB STERN STB Set the location for selected device Use BOW or STERN in a...

Page 14: ...t of devices found can fill more than one screen A scroll bar indicates the position of the selected item The joystick s operates the thrusters as normal while info is displayed This will be useful fo...

Page 15: ...AN bus error status for the panel Showing no error and signal condition is good Example showing lots of error and very bad signal conditions DIAGNOSTIC DISPLAY Rx Error Count Receive error counter Err...

Page 16: ...CELSIUS Default FAHRENHEIT Set the panel temperature displaying unit WHEN RETRACT IS OUT Values NO WARNING Default WARNING EVERY 10sec Select WARNING EVERY 10sec for external buzzer or lamp warning ev...

Page 17: ...larm De scription pages in the Auto Reset column you can see which alarms that are auto reset SPECIFIC ALARMS STOP BUTTON Pressing the STOP button on a hydraulic panel will activate the dump valve and...

Page 18: ...shown in a dual stern thruster setup Battery indicator will be shown here in a single DC electric stern thruster setup BOW STERN BOW STB STERN STB Examples of display view for di erent panels applica...

Page 19: ...V thrusters Motor temperature indicator From 70 C 158 F to 130 C 266 F Symbol shown when a DC Thruster is used in a dual bow or dual stern setup Proportional Thruster Display Symbols EN MC_0053 Thrust...

Page 20: ...light in display and continous short beeps Voltage below 8 5V 15V 12V 24V system Temperature above 110 o C 230 o F None 4 Red backlight in display and continous short beeps If one or more of the thrus...

Page 21: ...Language English Backlight Level 5 Backlight Night Color Green Backlight Nightlevel 1 Timer Auto O 05 min Hold Calibration 70 Bow and Stern All system devices will be erased from memory Setup procedu...

Page 22: ...r 2 3 Motor relay fault Turn off thruster battery main switch Thruster must be serviced by author ized personel 8 Critical Error 2 3 PPC output fail PPC must be sent for service 9 Low Motor Current 2...

Page 23: ...1 2 3 Any Stabilizer alarm See stabilizer panel for more info 28 AC Motor Overtemp Yes 1 2 3 Hydraulic AC motor power pack over temp Higher than 120 C 248 F Stop running and wait for tempera ture to d...

Page 24: ...20mA sensor short circuit Wires shorted or sensor defective check wiring sensor Replace sensor 10505 0 13 PHC AI 2 Open Circuit Analog Input 2 4 20mA sensor open circuit Sensor not connected or wire b...

Page 25: ...0 55 PHC ECI Cooling Pump Overtemp ECI cooling pump temperature higher than 100 C 212 F Check ECI cooling pump for damages Replace ECI cooling pump 10524 0 100 PHC ECI Cooling Pump No Communication No...

Page 26: ...26 3059 10 2019 PJC 221 222 MC_0037 Notes EN...

Page 27: ...Thruster AMS PPC etc Bow Bow STB Stern Stern STB Fill in the type location and serial numbers of the S link devices installed Keeping this as a reference will make the setup procedure easier Note Type...

Page 28: ...cument was correct at the time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the produc...

Reviews: