15
3059
10
2019
-
PJC 221 & 222
Information - PDC101 & PDC201
EN
EN
MC_0098
MC_0098
PDC101 and PDC 201
(Controller for AC electric thrusters)
Motor Speed: RPM on motor output shaft
Motor Power: Motor power consumption in % (PDC201 only)
Motor Temp: Temperature measured in motor
Thrust:
Thrust level from joystick/hold buttons
PDC-301
(SAC controller)
Motor : speed (rpm), temperature (°C/°F), power (kW), AC current (A) & AC voltage (V).
Thrust: Joystick thrust (%)
Information - PHC 3 & PHC024
EN
MC_0099
PHC-3 and PHC024
(Controller for hydraulic thrusters)
Oil Pressure: Oil pressure measured at system oil tank
Oil Temp:
Temperature measured inside the oil tank
Bow Thrust: Thrust level from joystick/hold buttons
Stern Thrust: Thrust level from joystick/hold buttons
FW:
Version number, Firmware
S/N:
Serial number of the PHC
Panel Information
EN
MC_0100
Display info about the control panel
FW:
Version number, Firmware
HW:
Version number, Hardware
S/N:
Serial number of the control panel
Voltage: S-link system voltage measured at the panel
•
Shows live update of S-link bus (CAN-bus) error status for the panel.
•
Showing no error and signal condition is good.
•
Example showing lots of error and very bad signal conditions.
DIAGNOSTIC DISPLAY
Rx Error Count
Receive error counter. Error during reception increments the value. After every successful reception the
value is decremented.
Tx Error Count
Transmit error counter. Error during transmit increments the value. After every successful transmit the value
is decremented.
Last Error
Indicates the error condition of the last error detected. If a message has been transferred or received
without error, it will show No Error.
Conditions: No Error, STUFF, FORM, ACK(Acknowledgment), BitRecessive, BitDominant & CRC.
Flag
BUS OFF: when Tx Error Count is greater than 255 and overfl owed. (Tx Error Count will show 0 when in
BUS OFF state)
WARNING: when Rx Error Count or Tx Error Count has reached 96 counts
PASSIVE: when Rx Error Count or Tx Error Count is more than 127 counts
(NB: When S-link devices are hot plugged or disconnected to the bus or powered (when AMS is
engaged and powering PPC and retract), it is not unnormal to see some values been incremented.
But they will quickly decrement to 0 again. This will not cause any communication issues.)
S-Link Diagnostic
EN
MC_0100
Hold Calibration
Menu System Information
Information - PPC, SR150000, SR61242
Joystick Calibration
EN
EN
EN
EN
MC_0098
MC_0098
MC_0098
MC_0098
Setup
Default in systems
without stabilizers
Calibrates the HOLD-function to get balanced thrust from the bow and stern thruster. If only one
thruster or PJC221/PJC211 you will not get any balanced thrust, but you can adjust the maximum
thrust from HOLD buttons. Hold-button represents 1/6 of the calibrated value.
(NB: HOLD CALIBRATION is not available until SETUP is completed.)
To start calibration, press the “+”-Hold button in the desired direction. For a fi rst time calibration, the thrusters will
start at 70%. A system previously calibrated will start with the last amount of thrust set.
Adjust power with the joystick.
Press the button below
to save the calibration values.
Press the button below
to cancel calibration without saving.
(NB: Setup calibration in one direction sets values for both directions.)
THRUSTER INFO
Display info about the thusters in the system.
The number of thrusters/controllers found is
shown in the upper right corner of the display.
The list of devices found can fi ll more than one screen. A scroll bar indicates the position of the selected item.
The joystick(s) operates the thrusters as normal while info is displayed. This will be useful for troubleshooting,
service and general system diagnostics. List will only show devices present on the S-link.
PPC
DC Speed Controller PPC520/ PPC820/ / PPC800
SR150000
Control unit for SRV80/SRV100/SRV130/SRV170/SRV210/SRH
SR61242
Control unit for SR80/SR100
Motor Temp: Temperature measured at the electric motor brushes
(Not implemented in SR61242)
Contr. Temp: Temperature measured inside the controller
(Not implemented in SR61242)
Voltage:
Motor Voltage measured at the controller
Thrust:
Thrust level from joystick/hold buttons
°/A/kW:
Retract angle (SR150000) / Motor Current (PPC) / Eff ect reading (PPC). SR150000 retract
angel is 0° when fully deployd, and about 90° when retracted.Put SR150000 in service mode
and operate the controller manually in an out to read the two end position angels for service
and installation.
(only for PJC2xx panels with HW V2)
This function is for calibrating the joysticks, and requires a pin code to enter. This option is for service personnel
only.
INFO
•
Move between menu items with the (stern) joystick.
•
Press the button below
to select the highlighted menu entry.
•
Press the button below
to return to the previous menu.