background image

 19

3059

10

2019

-

PJC 221 & 222

AC Thrusters:

Hydraulic Thrusters:

Retractable Thrusters:

DC Thrusters:

Motor temperature indicator.

Hydraulic oil temperature indicator.

Symbol shown when the thruster deploys.

Symbol shown when the thruster retracts.

Symbol shown when the thruster is in position OUT.
When the thruster is deployed and no input is given 

via the joysticks/buttons over a 10 second period, 

the panel will give an audible signal every 10th 

second to tell that the truster is still deployed. 

Battery indicator.

From 8.5V to 12V for 12V thrusters, 

15V to 24V for 24V thrusters

Motor temperature indicator.

From 70°C/ 158°F to 130°C/266°F.

Battery indicator.

From 8.5V to 12V for 12V thrusters, 

15V to 24V for 24V thrusters

Motor temperature indicator.

From 70°C/ 158°F to 130°C/266°F.

Symbol shown when a DC Thruster is

 used in a dual bow or dual stern setup:

Proportional Thruster Display Symbols

EN

MC_0053

Thrust power and direction, Bow thruster(s)

Input from bow joystick on this panel.

The thrust indicator will be shown in this position on a single 

joystick panel if the thruster is defi ned as a bow thruster

Indicating amount of thrust set by other control units in the system, i.e additonal 

PJC panels, 8700 Retract panel, input via 8730 S-link external switch interface, 

S-link remote control etc.

If two or more units are set to run the thruster in 

opposite direction, this information will not be shown.

Thrust power and direction, Stern thruster(s)

Input from stern joystick on this panel

The thrust indicator will be shown in this position on a single joystick panel if the 

thruster is defi ned as a stern thruster.

Proportional Thruster Display

EN

MC_0053

Status indicators for bow 

thruster. (Port bow thruster 

in a dual bow thruster setup).

Runtime indicator will be shown here 

in a single DC  electric bow thruster 

setup.

Status indicators for stern thruster. (Port 

bow thruster in a dual stern thruster 

setup)

Runtime indicator will be shown here 

in a single DC  electric stern thruster 

setup.

Status indicators for starboard 

bow thruster. Only shown in

a dual bow thruster setup. 
Battery indicator will be 

shown here in a single DC

electric bow thruster setup.

Status indicators for starboard 

stern thruster. Only shown in a 

dual stern thruster setup.
Battery indicator will be shown 

here in a single DC electric stern thruster 

setup. 

BOW

STERN

BOW-STB

STERN-STB

Examples of display view for diff erent panels applications:

PJC211:

DC Electric Bow thruster

PJC221:

Hydraulic Bow thruster

PJC221:

AC Electric Bow thruster

PJC212:

DC Electric Bow thruster

DC Electric Stern Thruster

PJC222:

Hydraulic Bow thruster

Hydraulic Stern Thruster

PJC222:

AC Electric Bow thruster

Hydraulic Stern Thruster

PJC211:

DC Electric Stern thruster

PJC212:

Dual DC Electric Bow thrusters

Dual DC Electric Stern thrusters

PJC222: 

Dual Hydraulic Bow thrusters

Dual Hydraulic Stern thrusters

PJC222:

Dual AC Electric Bow thrusters

Dual AC Electric Stern thrusters

PJC221:

Dual AC Electric Bow thrusters

PJC221:

Dual Hydraulic Bow thrusters

PJC221 

 PJC222 

  PJC211 

 PJC212 

 

 

Summary of Contents for S-linkControl Panel PJC221

Page 1: ...SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway www side power com Document id Revision Date 3059 10 Control Panels PJC 221 PJC 222 To download your language go to www side power com K e e p t...

Page 2: ...System PDC 101 Setup 10 AC System PDC 201 Setup 10 AC System PDC 301 Setup 11 DC System Automatic Main Switch Setup 12 DC System PPC SR150000 SR61242 Setup 12 DC System RCRS 1 RCRS 2 Setup 13 DC Syste...

Page 3: ...ing to international or special national regulations Instructions in this guide cannot be guaranteed to comply with global electric mechanic regulations classification rules It is the installers respo...

Page 4: ...he direction of the arrows at select ed power Press for more and for less power 6 steps If any control unit are running the thruster in opposite direction to the hold function the hold function will b...

Page 5: ...EN 60533 Weight 215 gr Description Minimum Maximum Units Comment Input voltage 9 31 Volt DC Powered from S Link Current Voltage 20 120 mA External Alarm Buzzer Voltage 31 Volt DC External Alarm Buzzz...

Page 6: ...222 Supply 12V 24V DC S link External alarm buzzer 12V 24V DC max 0 5A Internal fuse relay External alarm buzzer connection Rear side of panel Connections for optional external buzzer audible alarm C...

Page 7: ...s can not be operated to auto setup is completed OR RUN SETUP DEVICES IN CONFLICT Detected devices in con ict Two or more thrusters defined as same instance bow stern bow STB Stern STB Run Setup proce...

Page 8: ...lve Pump Control will then not be able to edit NB Pump Control Auto must only be used on PHC 024 with rmware V 1 008 or higher Cooling Pump Values Always Running Temp Controlled default When the optio...

Page 9: ...o protect the thruster during deceleration and will close while thruster is running By selecting with Bypass Valve you activate this signal and addition change ramp parameters to match this setup All...

Page 10: ...display and thruster s at the right side of the display Direction Values NA Not Available AC System PDC 101 Setup AC System PDC 201 Setup EN EN MC_0096 MC_0096 PDC 201 Location Values BOW STERN BOW ST...

Page 11: ...uster location should be set as BOW STB or STERN STB This so the hydraulic controller are shown at the left side in display and thruster s at the right side of the display Direction Values Normal defa...

Page 12: ...his so the hydraulic controller are shown at the left side in display and thruster s at the right side of the display Direction Values Normal default Inverted Switches between Normal and Inverted runn...

Page 13: ...t sideways when both thrusters are operated simultanously with input from the remote only MSI8730 Location Values BOW STERN BOW STB STERN STB Set the location for selected device Use BOW or STERN in a...

Page 14: ...t of devices found can fill more than one screen A scroll bar indicates the position of the selected item The joystick s operates the thrusters as normal while info is displayed This will be useful fo...

Page 15: ...AN bus error status for the panel Showing no error and signal condition is good Example showing lots of error and very bad signal conditions DIAGNOSTIC DISPLAY Rx Error Count Receive error counter Err...

Page 16: ...CELSIUS Default FAHRENHEIT Set the panel temperature displaying unit WHEN RETRACT IS OUT Values NO WARNING Default WARNING EVERY 10sec Select WARNING EVERY 10sec for external buzzer or lamp warning ev...

Page 17: ...larm De scription pages in the Auto Reset column you can see which alarms that are auto reset SPECIFIC ALARMS STOP BUTTON Pressing the STOP button on a hydraulic panel will activate the dump valve and...

Page 18: ...shown in a dual stern thruster setup Battery indicator will be shown here in a single DC electric stern thruster setup BOW STERN BOW STB STERN STB Examples of display view for di erent panels applica...

Page 19: ...V thrusters Motor temperature indicator From 70 C 158 F to 130 C 266 F Symbol shown when a DC Thruster is used in a dual bow or dual stern setup Proportional Thruster Display Symbols EN MC_0053 Thrust...

Page 20: ...light in display and continous short beeps Voltage below 8 5V 15V 12V 24V system Temperature above 110 o C 230 o F None 4 Red backlight in display and continous short beeps If one or more of the thrus...

Page 21: ...Language English Backlight Level 5 Backlight Night Color Green Backlight Nightlevel 1 Timer Auto O 05 min Hold Calibration 70 Bow and Stern All system devices will be erased from memory Setup procedu...

Page 22: ...r 2 3 Motor relay fault Turn off thruster battery main switch Thruster must be serviced by author ized personel 8 Critical Error 2 3 PPC output fail PPC must be sent for service 9 Low Motor Current 2...

Page 23: ...1 2 3 Any Stabilizer alarm See stabilizer panel for more info 28 AC Motor Overtemp Yes 1 2 3 Hydraulic AC motor power pack over temp Higher than 120 C 248 F Stop running and wait for tempera ture to d...

Page 24: ...20mA sensor short circuit Wires shorted or sensor defective check wiring sensor Replace sensor 10505 0 13 PHC AI 2 Open Circuit Analog Input 2 4 20mA sensor open circuit Sensor not connected or wire b...

Page 25: ...0 55 PHC ECI Cooling Pump Overtemp ECI cooling pump temperature higher than 100 C 212 F Check ECI cooling pump for damages Replace ECI cooling pump 10524 0 100 PHC ECI Cooling Pump No Communication No...

Page 26: ...26 3059 10 2019 PJC 221 222 MC_0037 Notes EN...

Page 27: ...Thruster AMS PPC etc Bow Bow STB Stern Stern STB Fill in the type location and serial numbers of the S link devices installed Keeping this as a reference will make the setup procedure easier Note Type...

Page 28: ...cument was correct at the time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the produc...