Operating Instructions
Chapter
9
UE 440/470
8 010 432/P097/14-03-05
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
79
Configuration
9.4
Configuration memory
The configuration of the ESPE (e.g. safety light curtain C 4000 Standard/Advanced) from
SICK AG connected via EFI can be saved in the UE 440/470.
The automatic reconfiguration is configured in the
Edit configuration draft
window, menu
Tools
, command
Configuration wizard...
.
When exchanging ESPE with the same type code, the configuration is transferred to the
ESPE automatically.
Fully decommission the system.
Exchange the ESPE as described in the operating instructions.
Recommission the system (see Chapter 8 "Commissioning" on Page 73).
The 7-segment display runs through the switch-on sequence and then shows
*
.
Any configuration saved in the safety controller of one or more pieces of ESPE is
transferred to the ESPE.
The 7-segment display then shows
&
.
If the configuration cannot be transferred to the ESPE (e.g. because the exchanged ESPE
is not exactly the same), the 7-segment display shows
-
.
Then reconfigure the ESPE and UE 440/470 if necessary.
!