MAINTENANCE AND REPAIR
7
71
8027439/V1-0/2022-02|SICK
Subject to change without notice
A D D E N D U M T O O P E R A T I N G I N S T R U C T I O N S | Track and trace cabinet TTC100-2
Fig. 37: Replacing the filters at the air inlets and outlets of the cabinet
Part no.
Description
5323683
Filter mat, square, 89 mm x 89 mm with beveled corners, for air
inlet and outlet of the ventilation.
Unit of 5
▸
Regularly check and, if necessary, replace the filter mats behind the covers for the air
inlets and outlets.
▸
Remove the covers from the air inlets and outlets. To do so, insert your finger into the
semi-circular recess in the cover.
▸
Carefully remove the cover from the front.
NOTE
The compressed side of the filter mat points to the fan wheel.
7.2
Replacing the controller
Part no.
Description
1117588
SIM2000-3L10A00
WARNING!
RISK OF INJURY FROM HOT SURFACES
Risk of burns due to hot surfaces on the controller during operation.
▸
Do not touch hot surfaces.
▸
Wear suitable safety gloves.
7.2.1
Removing connecting cables
▸
Interrupt the supply voltage to the cabinet.
▸
Disconnect all plug-in terminal blocks from the controller.
NOTE!
Make sure that no wires are pulled out from the terminal blocks.
Replacing