3
PRODUCT DESCRIPTION
16
8027439/V1-0/2022-02|SICK
A D D E N D U M T O O P E R A T I N G I N S T R U C T I O N S | Track and trace cabinet TTC100-2
Subject to change without notice
3.2.3
Components for voltage supply
Fig. 4:
Power supply units
Legend
1
Connection to the local mains voltage (AC 100 ... 264 V / 50 ... 60 Hz)
2
Input voltage connection (wired at the factory)
3
Potentiometer for the output voltage
4
Connection for 24 V output voltage
5
Mounting strap
•
The power supply units of the cabinet deliver the 24 V supply voltage for all
components installed in the cabinet as well as the connected sensors.
•
The cabinet does not have a master switch for the incoming supply voltage.
Fig. 5:
Terminal blocks for connecting to a 24 V voltage supply
Legend
A
24 V terminals for connecting ICR cameras to the voltage supply
(each protected via 2 circuit breakers)
B
24 V terminals with fuse modules for connecting internal components
and external sensors to the voltage supply
1
Terminals
2
Fuse module
3
LED display
Power supply units
Connection to 24 V
voltage supply