3
PRODUCT DESCRIPTION
28
8027439/V1-0/2022-02|SICK
A D D E N D U M T O O P E R A T I N G I N S T R U C T I O N S | Track and trace cabinet TTC100-2
Subject to change without notice
3.6
System requirements
The operation site of the track and trace cabinet must have the following features:
•
Closed or covered room
•
Flat and firm surface
•
Low-vibration environment
•
Protected from wind and free of drafts
•
No direct sunlight
•
Clean and dry (air humidity 90%, non-condensing)
•
Room temperature of 0 °C to +50 °C
Regardless of the space required for the components, there must be enough space at
the operation site for the following activities:
•
Opening the cabinet doors completely
•
Cleaning, maintenance, and service
The cabinet requires both a stable, secure frame to prevent skewing and a sufficient load-
bearing capacity.
The frame must be assembled in such a way that it is free of vibrations and oscillations.
To operate the cabinet, the following are required:
•
Supply voltage: AC 100 ... 264 V / 50 ... 60 Hz
•
Host computer
with
RS-232, RS-422 or Ethernet data interface for further processing
of the recorded data. Due to the use of an external fieldbus module, integration into
other fieldbus connections is possible.
•
The system is configured via a configuration PC with the SOPAS configuration software
installed.
•
The configuration PC is connected to the controller of the cabinet via Ethernet.
Requirements on
the operation site
Mounting
requirements
Electrical installation
requirements
Requirements for the
configuration PC