3
PRODUCT DESCRIPTION
24
8027439/V1-0/2022-02|SICK
A D D E N D U M T O O P E R A T I N G I N S T R U C T I O N S | Track and trace cabinet TTC100-2
Subject to change without notice
3.4.3
Data processing and data output
Fig. 13: How data are processed in the controller
•
All information converges in the SIM2000-2 Prime controller.
•
The controller typically processes the trigger and encoder signal and assigns the
measurement results of the individual sensors to the respective object.
•
It is also possible to use the SOPAS configuration tool to configure event-dependent
assessment conditions as well as filters and sorters for the output formatting of the
measurement and reading results.
•
The data from the SIM2000-2 Prime controller is output to the downstream customer
system via physical data interfaces.
•
Several output formats (output telegrams) can be defined for the data output.
NOTE!
An output format for the heartbeat can also be defined.
Data processing
in the controller
Data output