Properties
Data
min. type max.
Switching voltage
HIGH active (U
eff
)
13.4 V
at U
v
= 16.8 V
Voltage LOW
0 V
2.5 V
Switching current
(referred to EXT_GND)
4 mA
150 mA
Time behaviour of output
without restart inhibit
Depends on scan rate
Activation on protective field (SF) clear
190 ms
Time behaviour of output
after 2 seconds
Depends on scan rate
Activation on protective field (SF) clear
2 s
Short-circuit protected
by monitoring of outputs
Fault: Leak current
2.1 mA
Fault: Interruption of GND cable.
The downstream control element
must recognise this status as LOW.
Pure load capacity
100 nF
Switching frequency
3 Hz
Pure load inductivity
2H
At low switching frequencies the max.
permissible load inductivity is higher.