PLS GB
156
8 009 810/OA87/13-09-04 Operating Instruction
•
PLS © SICK AG
•
Industrial Safety Systems
•
Germany
•
All rights reserved
7. Has the maximum stopping or run-on time of the machinery
been checked and is it indicated (on the machine and/or in
the machine documents) and documented?
Yes
No
8. Is the required safety distance maintained between the
NCSD and the nearest danger area?
Yes
No
9. Are the NCSD devices properly mounted and secured
against displacement after adjustment?
Yes
No
10. Are the required safety measures to prevent electric shock
effective (protection class)?
Yes
No
11. Is the command unit for resetting the (NCSD) safety device
or for restarting the machine present and properly installed?
Yes
No
12. Are the outputs of the NCSD (OSSD) connected up in accor-
dance with the required control category, and do they comply
with the circuit diagrams?
Yes
No
13. Has the protective function been checked in accordance with
the test instructions in this document?
Yes
No
14. Are the specified protective functions effective at all settings
of the mode selector switch?
Yes
No
15. Are the switching elements (e.g. contactors, valves) actuated
by the NCSD monitored?
Summary of Contents for PLS 10X-317