PLS GB
166
8 009 810/OA87/13-09-04 Operating Instruction
•
PLS © SICK AG
•
Industrial Safety Systems
•
Germany
•
All rights reserved
Properties
Data
min. type max.
Optical data
Scan angle
180°
Angular resolution
0.5°
1° by
pixel
blanking
Protective field
Range (radius)
1,5 m
Reflectance of object
1.8 %
(diffuse)
Resolution 50
mm
Safety category
DIN V 19250
Requirement class 4
EN 954-1
Category 3
IEC/EN 61496-1
The EC type testing was performed in accordance with BIA test
recommendations which to a great extent correspond to the current
draft standard IEC 61496-3:1999
Type 3
Type 3
Type 3
Warning
field
Range (radius)
50 m
Reflectance at 15 m and 80 mm
object diameter
20%
Safety category
None
Measuring range
Range (radius)
50 m
Reflectance
Graph
(see p. 67 of PLS TD)