PLS GB
162
8 009 810/OA87/13-09-04 Operating Instruction
•
PLS © SICK AG
•
Industrial Safety Systems
•
Germany
•
All rights reserved
10. Technical data PLS 10X-317
The most important technical data of the PLS are listed below.
Electrical data
The characteristics are measured at the connection corner (unless
otherwise specified).
Properties
Data
min. type max.
Supply voltage (U
v
)
16.8 V
24.0 V
28.8 V
Reverse-polarity protected, via isola-
ting transformer to EN 60742 (also
vehicle charger)
Permissible residual ripple (V
RMS
)
500 mV
The supply voltage limits must not be
exceeded or undershot.
Response time (adjustable
via scan rate)
double-speed
2 x 40 ms
sixteen-speed
16x40
ms
Power-up times
On voltage ON
6 s
Power consumption (no load)
17 W
Summary of Contents for PLS 10X-317