
19
List of figures
1.
2.
3.
4.
5.
6.
Reference contour field, shown in blue-green in this document.............................17
7.
8.
9.
Access protection: detection of a person when accessing a hazardous area........19
10. Mobile hazardous area protection: detection of a person when a vehicle
11. Prevent crawling beneath...........................................................................................21
12. Prevent stepping over.................................................................................................22
13. Unsecured areas.........................................................................................................23
14. Mounting with deflector plates (example).................................................................24
15. Mounting in an undercut (example).......................................................................... 24
16. Mounting in vehicle paneling (example)....................................................................25
17. Overrun of the protective field in front of an opening.............................................. 26
18. Tolerance band of the contour as reference field (protective field within the pro‐
tected opening, edge of the protected opening = reference contour).................... 27
19. Stationary application with horizontal scan plane for hazardous area protection.28
20. Protection against reaching over when mounted low (dimensions in mm)............ 31
21. Protection against reaching over when mounted high (dimensions in mm).......... 31
22. Scan plane at ankle height........................................................................................ 32
23. Scan plane at calf height........................................................................................... 33
24. Distance of the protective field from the wall...........................................................34
25. Stationary application in vertical operation for hazardous point protection.......... 35
26. Stationary application in vertical operation for access protection..........................38
27. Mobile application in horizontal operation for hazardous area protection.............41
28. flat-rate supplement ZF for lack of ground clearance.............................................. 42
29. Minimum supplement for lack of ground clearance................................................ 43
30. Stopping distance as a function of the vehicle’s speed...........................................44
31. Recommended fitting height..................................................................................... 46
32. Recommended fitting height for inverted mounting................................................ 46
33. Dual-channel and separate connection of the OSSDs of an OSSD pair.................49
34. No potential difference between load and protective device.................................. 50
35. Connection diagram with FE on the M12 plug connector....................................... 50
36. Connection diagram with FE on alternative FE connection..................................... 51
37. Prevent crawling beneath...........................................................................................57
38. Prevent stepping over.................................................................................................57
39. Mounting the safety laser scanner directly...............................................................58
40. Connection of the OSSDs of an OSSD pair...............................................................60
41. No potential difference between load and protective device ................................. 60
42. Pin assignment of the connecting cable (male connector, M12, 5-pin, A-coded). 61
43. Alternative FE connection.......................................................................................... 61
44. Software controls........................................................................................................64
45. Configuration...............................................................................................................67
46. Overview...................................................................................................................... 68
47. Functional scope.........................................................................................................70
48. Identification............................................................................................................... 71
49. Application.................................................................................................................. 73
50. Monitoring plane.........................................................................................................74
51. Reference contour field..............................................................................................78
LIST OF FIGURES
19
8017784/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
147
Subject to change without notice