The following mounting method has the advantage that both safety laser scanners can
be mounted at a similar height. Nonetheless, there is enough space between the scan
planes.
≥
100 mm
Figure 78: Mounting the upper safety laser scanner with the optics cover facing upward and
mounting the lower safety laser scanner with the optics cover facing downward
≥
100 mm
Figure 79: Mounting the upper safety laser scanner with the optics cover facing downward and
mounting the lower safety laser scanner with the optics cover facing upward
Mount several safety laser scanners crosswise
If you tilt opposite safety laser scanners with respect to one another, both safety laser
scanners must be tilted upward. (If mounted upside down, both safety laser scanners
must be tilted downward.)
In any event, ensure that the protective field is at the right height so that crawling
beneath and climbing over are prevented and so that the set resolution matches the
mounting height.
ANNEX
18
8017784/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
145