6.2.1
microScan3 Core
Table 3: System plug and connections: microScan3 Core
Safety laser scanner
Suitable system plug
Plug connector
microScan3 Core I/O AIDA
MICSX-ABHZZZZZ1 (part number: 2087958)
•
Connecting cable with M12 plug
connector,
•
Alternative FE connection,
6.3
Pin assignment
You will find the pin assignment for the individual plug connectors in the following.
6.3.1
Connecting cable with M12 plug connector
Voltage is supplied and local outputs are connected via the connecting cable with a
5-pin, A-coded M12 male connector.
2
1
4
3
5
Figure 42: Pin assignment of the connecting cable (male connector, M12, 5-pin, A-coded)
Table 4: Pin assignment of the connecting cable with M12 plug connector
Pin
Marking
Function
1
+24 V DC
Supply voltage (+24 V DC)
2
3
0 V DC
Supply voltage (0 V DC)
4
5
FE
Functional earth/shield
Thread
FE
Functional earth/shield
6.3.2
Alternative FE connection
Figure 43: Alternative FE connection
Screw connection of the alternative FE connection
•
Screw: M5 × 12
•
Screw head: hexagon with slot, width across flats WAF 8
•
Tightening torque: 3.5 Nm to 5.0 Nm
ELECTRICAL INSTALLATION
6
8017784/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
61
Subject to change without notice