Mounting with deflector plates
Figure 14: Mounting with deflector plates (example)
b
Attach the deflector plates
1
so that it is not possible to step into unsecured
areas.
b
Attach the deflector plates so that they lie outside the scan plane.
Mounting in an undercut
Figure 15: Mounting in an undercut (example)
b
Mount the safety laser scanner in an undercut so that no-one can enter the
unsecured areas.
b
Make the undercut at least deep enough
1
, that it covers the unsecured areas
completely and no one can enter the unsecured areas.
b
Prevent crawling beneath the undercut. Design the undercut to be so low
2
, that
no one can crawl into it.
4
PROJECT PLANNING
24
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
8017784/1ELL/2022-01-21 | SICK