5
COMMISSIONING AND OPERATION
28
Operating Instructions | InspectorP Rack Fine Positioning
8024534 / / 2019-08-19
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Byte 10
Example 4
<01>
<00>
<00>
<7D>
<00>
<7D>
<01>
<5E>
<06>
<82>
Interpreta-
tion exam-
ple 4
Single and double deep
parameterization
125/10 mm
= 12.5 mm
125/10 mm
= 12.5 mm
350 mm
1,666 mm
All parameters are evaluated as WORD in the control.
As an answer to parameterization in Single and Double deep modes, the device sends
status bytes <00><20>, which are reset to <00><00> after successful parameteriza-
tion.
Command 5: “Parameterization of evaluation with target region for single deep:
<02> <00>”
If the first byte (Command_H) equals <02>, then the device evaluates the 9 bytes fol-
lowing the command bytes as parameters for specialist processing with several posi-
tioning marks in the image for Single deep mode. An evaluation mode with a target re-
gion is usually used for this purpose. In this evaluation mode, only a section of the en-
tire camera image is evaluated, not the whole image. Non-relevant circles are hidden.
Activation leads to parameter change, but not to recalibration:
Byte 1
Byte 2
Byte 3
Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
Byte
10
Byte
11
Designa-
tion
Com-
mand_H
Com-
mand_L
CircSel
OffX_H OffX_L OffY_H OffY_L TolX_H TolX_L TolY_H TolY_L
Function
Command
Evaluate
mode
Relative offset to
deviation X in
1/10 mm
Relative offset to
deviation Y in
1/10 mm
Tolerance X in
1/10 mm
Tolerance Y in
1/10 mm
Example 5
<02>
<00>
<09>
<00>
<64>
<FF>
<38>
<01>
<F4>
<01>
<2C>
Interpreta-
tion exam-
ple 5
Specialist single deep pa-
rameterization
“9 target re-
gion - best di-
ameter”
100/10 mm
= 10 mm
-200/10 mm
= -20 mm
500/10 mm
= 50 mm
300/10 mm
= 30 mm
The
Selection
parameter (Evaluation mode) in byte 3 is evaluated as BYTE in the con-
trol. All other parameters are evaluated as WORD in byte 4 to byte 11.
As an answer to specialist single deep parameterization, the device sends status bytes
<00><40>. These are reset to <00><00> after successful parameterization.
Command 6: “Parameterization of evaluation with target region for double deep:
<03> <00>”
If the first byte (Command_H) equals <03>, then the device evaluates the 9 bytes fol-
lowing the command bytes as parameters for specialist processing with several posi-
tioning marks in the image for Double deep mode. An evaluation mode with a target
region is usually used for this purpose. In this evaluation mode, only a section of the
entire camera image is evaluated, not the whole image. Non-relevant circles are hid-
den. Activation leads to parameter change, but not to recalibration:
Byte 1
Byte 2
Byte 3
Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
Byte
10
Byte
11
Designa-
tion
Com-
mand_H
Com-
mand_L
CircSel
OffX_H OffX_L OffY_H OffY_L TolX_H TolX_L TolY_H TolY_L