4
INSTALLATION
16
Operating Instructions | InspectorP Rack Fine Positioning
8024534 / / 2019-08-19
2.
Undo the screws on the hinged cover and open the cover.
3.
Insert the microSD memory card.
4.
Close the hinged cover. Make sure that the cover is completely flush with the
housing.
5.
Tighten the screws on the hinged cover again.
6.
Switch on the supply voltage for the device.
7.
In the SICK AppManager, in the
Device
window, click on the
Clone
button.
From now on, the device will back up the current parameter set on the mi-
croSD memory card.
4.1.4
Installing firmware updates
Firmware updates are installed via SICK AppManager:
1.
Pull the file with the firmware update into the
Firmware
window with drag &
drop.
2.
Select the file you want to install.
3.
Click on the
Install
button in the lower right section of the window to install the up-
date.
4.2
Mounting
4.2.1
Mounting procedure
The device is delivered with pre-mounted illumination, pre-focused optics, pre-installed
software and pre-configured defaults. This enables quick and easy commissioning.
The optics are already pre-focused at a distance which is suitable for most applica-
tions. It might be a good idea to optimize the focus position in rare cases,
see Figure 8:
The procedure for mounting the device is divided into the following steps:
•
Mount device with a view to the positioning mark.
•
Connect device to interfaces and supply voltage.
•
Align device with aiming laser.
4.2.2
Mounting device
Install the device to the mechanics with the bracket so that the device points vertically
to the positioning mark on the rack.
NOTE
It should be mounted so that it is exposed to as little shock and vibration as pos-
sible. Ensure that the position of the device is not moved by vibrations during op-
eration.
After switching on the supply voltage, the device starts and automatically activates the
aiming laser. The aiming laser helps align the device. The device projects two red laser
points on the rack, signaling the viewing direction of the camera. The center of the im-
age is between the two points. Align the device so that the positioning mark on the
rack is between the two laser points and is therefore in the center of the image. Press
the arrow button to switch the aiming laser on and off.